EU DPP Battery Performance Ontology
language en

EU DPP Battery Performance Ontology

Release: 2026-07-07

Modified on: 2026-09-01
This version:
https://w3id.org/eudpp/battery-performance/0.3.0
Revision:
Version 0.3.0 DRAFT
Issued on:
2026-07-07
Authors:
Marc-Andree Wolf
Nader Jelassi
Contributors:
Arnab Sinha
Source:
https://eur-lex.europa.eu/eli/reg/2023/1542/oj
Download serialization:
JSON-LD RDF/XML N-Triples TTL
License:
Apache 2.0
Visualization:
Visualize with WebVowl
Cite as:
EU DPP Battery Performance Ontology. Draft version 0.3.0.
Provenance of this page
Ontology Specification Draft

EU DPP Battery Performance Ontology: Overview back to ToC

This ontology has the following classes and properties.

Classes

Object Properties

Data Properties

Annotation Properties

EU DPP Battery Performance Ontology: Description back to ToC

Developed against the CIRPASS-2 CORE ontology v2.0.5 (refresh of 25 August 2026; P_DPP v2.0.6 of 27 August 2026, MAT v1.0.2). External references are pinned to these versions.

Cross-reference for EU DPP Battery Performance Ontology classes, object properties and data properties back to ToC

This section provides details for each class and property defined by EU DPP Battery Performance Ontology.

Classes

Accident Eventc back to ToC or Class ToC

IRI: https://w3id.org/eudpp/battery-performance#AccidentEvent

An accident affecting the battery, including when incorporated in the equipment it is powering. Specialises the generic ProductEvent class of the CORE event module, of which MaintenanceEvent is a sibling: an accident is not a maintenance operation. The link to the battery is provided by the CORE event mechanism (no dedicated object property in this module).
Is defined by
https://w3id.org/eudpp/battery-performance
has super-classes
Product Event c
is in domain of
information on accidents dp

Battery Durabilityc back to ToC or Class ToC

IRI: https://w3id.org/eudpp/battery-performance#BatteryDurability

Battery-specific durability data: expected lifetime in calendar years and in charge-discharge cycles, number of full cycles, energy and capacity throughput, capacity threshold for exhaustion. Specialises the cross-sectoral Durability quality indicator (ESPR Art. 2 (22)).
Is defined by
https://w3id.org/eudpp/battery-performance
has super-classes
Durability c
is in domain of
capacity threshold for exhaustion dp, expected lifetime in calendar years dp, expected lifetime: number of charge-discharge cycles dp
is in range of
has battery durability op

Battery Performancec back to ToC or Class ToC

IRI: https://w3id.org/eudpp/battery-performance#BatteryPerformance

Container for the electrochemical performance and in-use state parameters of a battery: capacity (rated, remaining, fade), voltage (minimum, maximum, nominal), power capability, round trip energy efficiency, self-discharge rates, internal resistance, cycle-life test parameters, and in-use event counters. Anchored under the cross-sectoral Property class, not under QuantitativeProperty: this is a container grouping several measured quantities, not a quantity itself, and would otherwise inherit hasMeasurementUnit, which has no meaning on a container.
Is defined by
https://w3id.org/eudpp/battery-performance
has super-classes
Property c
is in domain of
C-rate of relevant cycle-life test dp, certified usable battery energy dp, cycle-life reference test dp, initial internal resistance of battery cell and pack dp, initial round trip energy efficiency dp, initial self-discharge rate dp, maximum permitted battery power dp, maximum voltage dp, minimum voltage dp, nominal voltage dp, original power capability dp, rated capacity dp, ratio between nominal battery power and battery energy dp, round trip energy efficiency at 50% of cycle life dp
is in range of
has battery performance op

Battery State Recordc back to ToC or Class ToC

IRI: https://w3id.org/eudpp/battery-performance#BatteryStateRecord

A dated record of the values a battery management system updates during operational life. One record per reading; the series of records is the history required by Annex XIII 4 and Annex VII Part B, which describe data that changes over the life of the product rather than a single snapshot. Anchored under dpp:Property and deliberately not under dpp:QuantitativeProperty: this is a container grouping several measured quantities, not a quantity itself, and would otherwise inherit dpp:hasMeasurementUnit, which has no meaning on a container. Which properties belong here follows the 'Data behavioural characteristic: static vs. dynamic' column of the BatteryPass-Ready Data Attribute Long List v1.3, not a local judgement.
Is defined by
https://w3id.org/eudpp/battery-performance
Source
https://eur-lex.europa.eu/eli/reg/2023/1542/oj
has super-classes
Property c
is in domain of
as-of date dp, capacity fade dp, capacity throughput dp, current self-discharge rate dp, energy round trip efficiency fade dp, energy throughput dp, evolution of self-discharge rates dp, internal resistance increase of pack dp, number of deep discharge events dp, number of full charging and discharging cycles dp, number of overcharge events dp, power fade dp, remaining capacity dp, remaining power capability dp, remaining round trip energy efficiency dp, remaining usable battery energy dp, state of certified energy (SOCE) dp, state of charge (SoC) dp, temperature information dp, time spent charging during extreme temperatures above boundary dp, time spent charging during extreme temperatures below boundary dp, time spent in extreme temperatures above boundary dp, time spent in extreme temperatures below boundary dp
is in range of
has battery state record op

Temperature Exposurec back to ToC or Class ToC

IRI: https://w3id.org/eudpp/battery-performance#TemperatureExposure

Container for the thermal exposure of the battery in use: operating temperature information, idle-state temperature range boundaries, and aggregated time spent (and spent charging) in extreme temperatures outside those boundaries. Anchored under the cross-sectoral Property class, not under QuantitativeProperty: this is a container grouping several measured quantities, not a quantity itself.
Is defined by
https://w3id.org/eudpp/battery-performance
has super-classes
Property c
is in domain of
temperature range idle state, lower boundary dp, temperature range idle state, upper boundary dp
is in range of
has temperature exposure op

Object Properties

has battery durabilityop back to ToC or Object Property ToC

IRI: https://w3id.org/eudpp/battery-performance#hasBatteryDurability

Links a battery to its durability data. Specialises the cross-sectoral dpp:hasProperty (Product -> Property); the chain BatteryDurability = dpp:Durability = QualityIndicator = QuantitativeProperty = Property was verified in P_DPP v2.0.0.
Is defined by
https://w3id.org/eudpp/battery-performance
has super-properties
has Property op
has domain
Battery c
has range
Battery Durability c

has battery performanceop back to ToC or Object Property ToC

IRI: https://w3id.org/eudpp/battery-performance#hasBatteryPerformance

Links a battery to its electrochemical performance and in-use state data.
Is defined by
https://w3id.org/eudpp/battery-performance
has super-properties
has Property op
has domain
Battery c
has range
Battery Performance c

has battery state recordop back to ToC or Object Property ToC

IRI: https://w3id.org/eudpp/battery-performance#hasBatteryStateRecord

Links a battery to one dated record of its in-use state. A battery carries as many records as there are readings; no ordering property is declared, the as-of date orders the series.
Is defined by
https://w3id.org/eudpp/battery-performance
has super-properties
has Property op
has domain
Battery c
has range
Battery State Record c

has temperature exposureop back to ToC or Object Property ToC

IRI: https://w3id.org/eudpp/battery-performance#hasTemperatureExposure

Links a battery to its in-use thermal exposure data.
Is defined by
https://w3id.org/eudpp/battery-performance
has super-properties
has Property op
has domain
Battery c
has range
Temperature Exposure c

Data Properties

as-of datedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#asOfDate

The date and time the values of this record were read. xsd:dateTimeStamp rather than xsd:dateTime: the time zone offset is then mandatory, so no separate offset property is needed.
Is defined by
https://w3id.org/eudpp/battery-performance
Source
https://eur-lex.europa.eu/eli/reg/2023/1542/oj
has domain
Battery State Record c
has range
date Time Stamp

C-rate of relevant cycle-life testdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#cRateOfCycleLifeTest

Measurement parameter for 'Expected lifetime: Number of charge-discharge cycles': applied charge and discharge rate in terms of rated capacity (C-rate) of the relevant cycle-life reference test. Unit: ampere per ampere-hour (A/Ah).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

capacity fadedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#capacityFade

The decrease over time and upon usage in the amount of charge that a battery can deliver at the rated voltage, with respect to the original rated capacity as declared by the manufacturer. Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

capacity threshold for exhaustiondp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#capacityThresholdForExhaustion

The percentage of SOCE (State of Certified Energy), above which the battery is still considered operational as EV battery in its current life, as provided by the economic operator. Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Durability c
has range
decimal

capacity throughputdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#capacityThroughput

The overall sum of the capacity throughput over the battery lifetime at a specific time during usage. Unit: ampere-hour (Ah).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

certified usable battery energydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#certifiedUsableBatteryEnergy

The usable battery energy according to the procedure in the UN GTR No 22 as determined during the certification of the vehicle. Unit: kilowatt-hour (kWh).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

current self-discharge ratedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#currentSelfDischargeRate

The change of the self-discharge rate in an idle state of the battery in reference conditions (temperature etc.) at aging parameter x, e.g. after a certain amount of storage time or number of cycles. Unit: percent per month (%/month).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

cycle-life reference testdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#cycleLifeReferenceTest

The reference test for 'Expected lifetime: Number of charge-discharge cycles'.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
string

energy round trip efficiency fadedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#roundTripEnergyEfficiencyFade

The decrease of round trip energy efficiency as percentage. Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

energy throughputdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#energyThroughput

The overall sum of the energy throughput over the battery lifetime at a specific time during usage. Unit: kilowatt-hour (kWh).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

evolution of self-discharge ratesdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#selfDischargeRateEvolution

The change of self-discharge over time and usage, as percentage calculated from the initial and current self-discharge rate. Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

expected lifetime in calendar yearsdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#expectedLifetimeCalendarYears

Expected lifetime under the reference conditions for which the battery has been designed, in calendar years. Unit: year.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Durability c
has range
decimal

expected lifetime: number of charge-discharge cyclesdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#expectedLifetimeCycles

Expected lifetime under the reference conditions for which the battery has been designed, in number of charge-discharge cycles (except for non-cycle applications).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Durability c
has range
integer

information on accidentsdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#accidentInformation

Information on accidents affecting the battery, including when incorporated in equipment it is powering, as a link to the relevant resource.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Accident Event c
has range
any U R I

initial internal resistance of battery cell and packdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#initialInternalResistance

'Quotient of change of voltage of a battery by the corresponding change in discharge current under specified conditions' (IEV 482 03 36), at begin of life, for battery cell and pack (module recommended). Unit: ohm.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

initial round trip energy efficiencydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#initialRoundTripEnergyEfficiency

The ratio of the net energy delivered by a battery during a discharge test to the total energy required to restore the initial state of charge by a standard charge (see Regulation (EU) 2023/1542, Annex IV (6)). Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

initial self-discharge ratedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#initialSelfDischargeRate

The self-discharge rate in an idle state of the battery in reference conditions (temperature etc.) at begin of life. Unit: percent per month (%/month).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

internal resistance increase of packdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#internalResistanceIncrease

The increase over time and upon usage of internal resistance, for the pack (cell and module recommended). Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

maximum permitted battery powerdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#maximumPermittedBatteryPower

The value of maximum permitted power the battery is rated for and reflects the data relevant for power limits. Unit: watt (W). Declared as Integer [W] in the BatteryPass-Ready long list; xsd:decimal retained per the Gap Analysis decision (open question to BatteryPass-Ready).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

maximum voltagedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#maximumVoltage

The upper voltage limit that the safe operation of the battery is rated for. Unit: volt (V).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

minimum voltagedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#minimumVoltage

The lower voltage limit that the safe operation of the battery is rated for. Unit: volt (V).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

nominal voltagedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#nominalVoltage

The suitable approximate value of the voltage used to designate or identify the battery. Unit: volt (V).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

number of deep discharge eventsdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#numberOfDeepDischargeEvents

The number of occasions, in which voltage has dropped below the lower operational limit as provided in the battery passport. In-use event counter.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
integer

number of full charging and discharging cyclesdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#numberOfFullCycles

In-use number of (full) charging and discharging cycles.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
integer

number of overcharge eventsdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#numberOfOverchargeEvents

The number of occasions, in which voltage has increased above the upper operational limit as provided in the battery passport. In-use event counter.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
integer

original power capabilitydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#originalPowerCapability

The amount of energy that a battery is capable to provide over a given period of time under reference conditions. Unit: watt (W).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

power fadedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#powerFade

The decrease over time and upon usage in the amount of power that a battery can deliver at the rated voltage. Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

rated capacitydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#ratedCapacity

The total number of ampere-hours that can be withdrawn from a fully charged battery under reference conditions. Unit: ampere-hour (Ah), or milliampere-hour (mAh) for LMT batteries.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

ratio between nominal battery power and battery energydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#powerToEnergyRatio

The suitable approximate value of the power capability used to designate or identify the battery, while the battery energy is determined in reference conditions to be defined. Unit: watt per watt-hour (W/Wh). Declared as Integer [W/Wh] in the BatteryPass-Ready long list; xsd:decimal retained per the Gap Analysis decision (open question to BatteryPass-Ready).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

remaining capacitydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#remainingCapacity

The corresponding in-use data attribute to rated capacity. Unit: ampere-hour (Ah).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

remaining power capabilitydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#remainingPowerCapability

The amount of energy that a battery is capable to provide over a given period of time under reference conditions at a distinct point in time during its usage. Unit: watt (W).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

remaining round trip energy efficiencydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#remainingRoundTripEnergyEfficiency

The in-use analogy to the initial round trip energy efficiency: the ratio of the net energy delivered by a battery during a discharge test to the total energy required to restore the initial state of charge by a standard charge. Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

remaining usable battery energydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#remainingUsableBatteryEnergy

The usable battery energy at the present point in the lifetime of a battery as determined according to the procedure in the UN GTR No 22. Unit: kilowatt-hour (kWh).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

round trip energy efficiency at 50% of cycle lifedp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#roundTripEnergyEfficiencyAt50PercentCycleLife

The ratio of the net energy delivered by a battery during a discharge test to the total energy required to restore the initial state of charge by a standard charge, measured at 50% of cycle life (see Regulation (EU) 2023/1542, Annex IV (6)). Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery Performance c
has range
decimal

state of certified energy (SOCE)dp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#stateOfCertifiedEnergy

The measured or on-board usable battery energy performance at a specific point in its lifetime, expressed as a percentage of the certified usable battery energy. Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

state of charge (SoC)dp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#stateOfCharge

The available energy or charge in a battery expressed as a percentage of rated capacity as declared by the manufacturer. When the battery's state of health is no longer equal to its initial condition, SoC refers to the maximum energy or charge that can be stored in the battery at the time of charging. Unit: percent (%).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

temperature informationdp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#temperatureInformation

Temperature information regarding operating environmental conditions. Unit: degree Celsius (°C).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

temperature range idle state, lower boundarydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#temperatureRangeIdleStateLowerBoundary

The lower boundary of the surrounding temperature range. Unit: degree Celsius (°C).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Temperature Exposure c
has range
decimal

temperature range idle state, upper boundarydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#temperatureRangeIdleStateUpperBoundary

The upper boundary of the surrounding temperature range. Unit: degree Celsius (°C).
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Temperature Exposure c
has range
decimal

time spent charging during extreme temperatures above boundarydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#timeSpentChargingInExtremeTemperaturesAboveBoundary

The aggregated time, in which the battery is charged, while temperatures above the upper boundary of the temperature range as defined in 'Temperature range idle state, upper boundary' are prevalent. Unit: minute.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

time spent charging during extreme temperatures below boundarydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#timeSpentChargingInExtremeTemperaturesBelowBoundary

The aggregated time, in which the battery is charged, while temperatures below the lower boundary of the temperature range as defined in 'Temperature range idle state, lower boundary' are prevalent. Unit: minute.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

time spent in extreme temperatures above boundarydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#timeSpentInExtremeTemperaturesAboveBoundary

The aggregated time, in which temperatures above the upper boundary of the temperature range as defined in 'Temperature range idle state, upper boundary' are prevalent. Unit: minute.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

time spent in extreme temperatures below boundarydp back to ToC or Data Property ToC

IRI: https://w3id.org/eudpp/battery-performance#timeSpentInExtremeTemperaturesBelowBoundary

The aggregated time, in which temperatures below the lower boundary of the temperature range as defined in 'Temperature range idle state, lower boundary' are prevalent. Unit: minute.
Is defined by
https://w3id.org/eudpp/battery-performance
has domain
Battery State Record c
has range
decimal

Annotation Properties

bibliographic Citationap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/bibliographicCitation

contributorap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/contributor

createdap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/created

creatorap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/creator

descriptionap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/description

issuedap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/issued

licenseap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/license

measurement unitap back to ToC or Annotation Property ToC

IRI: https://w3id.org/eudpp/battery-performance#measurementUnit

The measurement unit of the annotated datatype property, as an IRI of the SI Digital Framework (https://si-digital-framework.org/SI/units/). Used because the values are plain typed literals in this pass and not dpp:QuantitativeProperty instances, so dpp:hasMeasurementUnit - an object property on QuantitativeProperty - does not apply. Where the unit has no IRI in the framework the annotation is absent and the unit stays in rdfs:comment; the cases are listed in the module header.
Is defined by
https://w3id.org/eudpp/battery-performance

modifiedap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/modified

preferred Namespace Prefixap back to ToC or Annotation Property ToC

IRI: http://purl.org/vocab/vann/preferredNamespacePrefix

preferred Namespace Uriap back to ToC or Annotation Property ToC

IRI: http://purl.org/vocab/vann/preferredNamespaceUri

referencesap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/references

sourceap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/source

titleap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/title

Legend back to ToC

c: Classes
op: Object Properties
dp: Data Properties

Acknowledgments back to ToC

The authors would like to thank Silvio Peroni for developing LODE, a Live OWL Documentation Environment, which is used for representing the Cross Referencing Section of this document and Daniel Garijo for developing Widoco, the program used to create the template used in this documentation.